Industrial Chillers Take The Advantage

Liquid-air cooling uses a fan blowing across the heat exchanger to remove the excess heat. The ambient air temperature (for liquid-air cooling) or ambient water temperature (for liquid-liquid cooling) will affect the unit’s cooling capacity. The chilled water from the chiller carries the heat away and returns to the water tank at a higher temperature. Therefore, the water chiller system is a kind of standard environmental protection and energy saving equipment. Industrial chiller is an effective solution to reduce or consume the heat emitted by the machine. Because whether water tower or air cooling solution, They are not up to the harsh environment.

When your cooling water isn’t cool enough, let a PCR Water Cooled Chiller provide the temperature you need. Condensers sized for city water, well water, cooling tower water or central chilled water systems. As you can see, industrial fluid chillers are a main component of many successful operations.

As an analogy, think of your home air conditioner, which also uses a typical refrigeration circuit. Inside the house, a blower forces warm return air through the evaporator, producing the cool air that flows into each room. Outside, a fan draws ambient air across the condenser and heats it; place your hand above the fan and you can feel the rejected heat from the system. The two liquids are separated and recombined during the absorption cycle. Due to the low pressure conditions in the chiller water can change phase easily.

Our industrial chillers use only EPA-approved refrigerants and the latest energy-efficient compressors. We also offer a city water bypass apparatus that operates without draining glycol. And for reduced energy consumption, look to our supplemental fluid coolers. They have a separate cooling tower to remove heat from the refrigerant.

Our chillers are designed to be easily portable, making it incredibly user friendly. They won’t get in the way and fit easily with the rest of your process equipment. It’s a cinch to install, remove, and relocate the chilling units as needed with minimal effort and time.

Laser Industry Chiller

Our expertise guarantees satisfied customers in a very short turnaround time. North Slope Chillers’ expert engineers will create a solution ideal for your application. At W & Z Machinery Sales, Inc., we offer a wide range of Portable Industrial Chillers including both Air-cooled Chillers and Water-cooled Chillers. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Witness your used chiller being load and performance tested either in person or by video. This is the proof you need to see with your own eyes before buying any used chiller.

Plastic extrusion process requires chilled water to function correctly. But extending the cooling time slows the production and increase the cost. Cooling time is the longest part of the total blow molding process and is often extended to get the heat from the part all the way through the wall to the mold. And finally the mold is opened and the finished hollow product is ejected. In blow molding, a plastic resin is heated into a liquid state and then pressed through a die head to form a hollow parison. Better heat transfer rate reduces the production cycle time and increases production efficiency.

For optimal performance, the laser optics typically require a stable operating temperature of 20°C ± 0.1°C, while ambient temperature may fluctuate between 23°C to 35°C in a room temperature environment. For example, fiber lasers have better cooling characteristics over other media due to their specific arrangement, which enables them to spread the heat over a larger surface area. Ion lasers are characterized by the generation of extreme heat during lasing and the need for elaborate cooling measures. Carbon dioxide lasers emit heat energy in the far-infrared and microwave region of the spectrum.

Utilizing high-performance variable speed motors, it offers low noise operation and reduced energy consumption by up to 50% compared to conventional compressor-based systems. By using environmentally-friendly R513A refrigerant, the Nextreme™ Chiller delivers similar performance with half the Global Warming Potential compared to traditional hydrofluorocarbons refrigerants. 1/2 hp commercial chillers by JBJ and Transworld aquatics are ideal for larger size cooling applications of freshwater and saltwater systems. If you do not have access to a building cooling tower or cooling tower water all year round to use for your condenser cooling, we offer our line of high efficiency dry fluid coolers. These fluid coolers can be located on the roof or ground and are designed to supply water or water glycol at 10° F higher than the ambient air dry bulb temperature. With fan cycling sensing the leaving fluid temperature we can maintain the correct cooling load with changing ambient temperatures.

A heat exchanger is a critical piece of equipment when you need to transfer heat between fluids for cooling or heating purposes in your industrial operations. All manner of industries, from HVAC to petrochemical, automotive, energy and many more make use of heat exchangers every day. As one of the largest providers of heat transfer cooling solutions in the United States, Thermal Care’s expertise is in the design of plant-wide cooling systems. A system typically is comprised of a central chiller, tank, cooling tower, and other components such as a heat exchanger, water treatment, filtration, variable frequency drive, and/or 3-way valves. A system can be used for a single process or multiple plant-wide applications.

This not only saves on energy but it also helps extend the life of the plastic fabrication equipment. Cooling systems are more than just a matter of comfort in Arizona, they are matter of health and safety. For commercial locations cooling expenses typically make up about 30% to 50% of the energy costs. With the cost of electricity always on the rise and the phasing out of HCFCs and CFCs there is an incredibly high demand for replacing large commercial air conditioning and refrigeration systems with chilling systems. The refrigeration cycle starts with the heating of the combined liquids.

Our chillers have been used to cool down facilities such as water parks, hospitals, plant farms, court houses, ice rinks, schools, and many more. Any types of industrial chillers to chill industrial equipment or processing. Coolsoon air cooled chillers and water cooled chillers serve full range of applications with any cooling capacity.

A chiller is a machine that removes heat from a liquid via a vapor-compression, adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream . As a necessary by-product, refrigeration creates waste heat that must be exhausted to ambience, or for greater efficiency, recovered for heating purposes. Vapor compression chillers may use any of a number of different types of compressors.

Leave a Reply

Your email address will not be published. Required fields are marked *